BPQWQ - NITROGEN (CONTAINED IN A DRESSER DIAL THERMOMETER)
- MSDS: BPQWQ
- Manufacturer: UNION CARBIDE CORP LINDE DIV
- Product Name: NITROGEN (CONTAINED IN A DRESSER DIAL THERMOMETER)
- National Stock Number: 6685-01-053-0649
Product Identification
Product ID:NITROGEN (CONTAINED IN A DRESSER DIAL THERMOMETER)
MSDS Date:08/01/1985
FSC:6685
NIIN:01-053-0649
MSDS Number: BPQWQ
Responsible Party
DANBURY, CT 06817-0001
US
Emergency Phone: 800-822-4357US/514-640-6400CANADA
Info Phone: 203-794-2000
Cage: 36346
Contractor
Telephone: 516-623-0100
Cage: 64467
Ingredients
NITROGEN
CAS: 7727-37-9
RTECS: QW9700000
Fraction By Weight: 100%
ACGIH TLV: ASPHYXIANT; 9293
Hazards
LD50 LC50 Mixture:NITROGEN IS A SIMPLE ASPHYXIANT
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:**MANUFACTURED ARTICLE** NO HAZARDS
ARE LIKELY AS THE AMOUNT OF NITROGEN GAS IS SO SMALL.NITROGEN IS AN
ASPHYXIANT; MODERATE AMOUNTS CAN CAUSE HEADACHE, DROWSINESS,
DIZINESS, EXCITATION, EXCESS SALIVA TION, VOMITING,
UNCONSCIOUSNESS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CONFIRMED OR SUSPECTED
CARCINOGENS.
Effects of Overexposure:NONE ARE LIKELY AS THE AMOUNT OF NITROGEN GAS
IS SO SMALL.NITROGEN IS AN ASPHYXIANT; MODERATE AMOUNTS CAN CAUSE
HEADACHE, DROWSINESS, DIZINESS, EXCITATION, EXCESS SALIVATION,
VOMITING, UNCONSCIOUSNESS .
Medical Cond Aggravated by Exposure:THE MANUFACTURER FOR THE NITROGEN
STATES THAT OVEREXPOSURE IS NOT LIKELY TO AGGRAVATE EXISTING
MEDICAL CONDITIONS.
First Aid
First Aid:INHALATION:REMOVE TO FRESH AIR.GIVE ARTIFICIAL RESPIRATION IF
NOT BREATHING.GIVE OXYGEN FOR DIFFICULT BREATHING.CALL A PHYSICIAN.
NOTE TO PHYSICIANS:THERE IS NO SPECIFIC ANTIDOTE. TREATMENT SHOULD
BE DIRECTED TOWARDS CONTROLLING SYMPTOMS.
Fire Fighting
Flash Point Method:TCC
Flash Point:NOT FLAMMABLE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:NITROGEN WILL NOT SUPPORT COMBUSTION. USE
APPROPRIATE MEDIA FOR THE SURROUNDING FIRE.
Fire Fighting Procedures:EVACUTE PERSONNEL FROM THE DANGER AREA.
Unusual Fire/Explosion Hazard:CONTAINERS OF NITROGEN UNDER PRESSURE MAY
BURST IN HEAT ABOVE 125F, HOWEVER THE MANUFACTURER STATES THAT THE
VOLUME OF N2 IN THE DEVICE IS ONLY 5-6CC.
Accidental Release
Spill Release Procedures:NOT APPLICABLE.
Neutralizing Agent:NONE APPLICABLE.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:(FOR NITROGEN)USE A NIOSH/MSHA APPROVED
RESPIRATOR IN ACCORDANCE WITH OSHA 29 CFR 1910.134.
Ventilation:NO SPECIAL REQUIREMENT.
Protective Gloves:NONE NEEDED.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE NEEDED.
Work Hygienic Practices:USE STANDARD HYGENIC PRACTICES.
Supplemental Safety and Health
READ PRECAUTIONS ON LABEL BEFORE USE.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:-321F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Pres:NOT APPLIC
Vapor Density:.967
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS (AT NORMAL TEMPERATURE AND
PRESSURE).
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR OXIDIZING AGENTS
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES.
Hazardous Decomposition Products:NONE KNOWN. HOWEVER, INCOMPLETE
COMBUSTION CAN RESULT IN TOXIC FUMES.
Disposal
Waste Disposal Methods:DISPOSE OF ANY CONTAINERS OR RESIDUE IN
ACCORDANCE TO FEDERAL, STATE OR LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.